Our range of products include cold finger cf 15, optical wat detector owd, dynamic stability loop, wax flow loop, cold finger mobile mcf2 and differential scale loop dsl.
  • Cold Finger CF 15
  • Cold Finger CF 15
  • Cold Finger CF 15
Cold Finger CF 15

Cold Finger CF 15

Rs 68 Lakh  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Weight90 Kg
Temperature Range30 to 120 degree C
Dimension55*59*118 cm
ConditionNew
PressureMax. 172 bar
Cold finger temperature-5 to 65 Degree C
Sample volume required60 - 80 ml
The Cold Finger is used to examine the wax content of crude oil and condensate. The PSL Coldfinger CF 15 is equipped with up to 15 measuring places for multi-place testing. It facilitates simultaneous testing of different chemicals on a single sample or testing of different inhibitor concentrations with the same sample.The Cold Finger is simulating the temperature difference, a cooled part (finger) is inserted into the stirred and heated oil. The contained waxy components start to precipitate on the surface of the cold finger cell. By weighing the deposition after a time at a set temperature, the deposition rate can be calculated. The final amount of deposition gives the total wax content.The wax deposition rate depends not only on the finger temperatures, but on sample temperature and stirring speed, too.


Features:

  • 15 measuring places for simultaneous test
  • Shorter measuring times
  • Samples can be separately removed during test
  • Improved handling
  • Highly precise measurings with weight calibrated cold finger cells
  • Software for documentation

Applications:

  • Determine wax content & paraffin deposition
  • Measure wax appearance temperature (WAT)
  • Development of inhibitors
  • Optimization of inhibitor concentrations
  • Quality control


Note: Price may vary depending on configuration & accessories.

Additional Information:

  • Item Code: CF15

View Complete details

get quote request a call back
  • Optical WAT Detector OWD
  • Optical WAT Detector OWD
  • Optical WAT Detector OWD
Optical WAT Detector OWD

Optical WAT Detector OWD

Rs 45 Lakh  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Powermax. 90 W
Voltage110 - 240 V~
UsageWax Appearance Temperature (WAT) Determination
Weight4.7 Kg
Dimension19 x 32 x 22 cm
Sample Volume< 1 ml
Accuracy / Repeatability0.1 DegreeC / 0.2 DegreeC
BrandPSL Systemtechnik
•Application
Optical WATdetermination
•Samplevolumevolume:< 1 ml
•Temp .-range: -20 .. 80 °C
•Resolution:0,1 °C
•Further benefits
Cross-polarisation filter method
Very low sample amount
Portablewith transport case

View Complete details

get quote request a call back
Dynamic Stability Loop

Dynamic Stability Loop

Rs 78 Lakh  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Temperature (Deg. Celsius)-10 t0 150degC
Voltage (V)230V
Weight (g)130 Kg
Automation GradeAutomatic
Power SourceAC supply
BrandPSL Germany
No of test loopsmax 6
DySL - Stress-Test of Oilfield Chemicals : The Dynamic Stability Loop (DySL) is designed for testing oilfield chemicals on long term stability under most rigorous conditions in laboratory. The DySL combines multi-loop testing of viscosity and filter blocking tests for low and high temperature under pressurized conditions.

In respect to extensive testing demands, the DySL is specially designed for multiple loop test runs.It comprises up to 6 test loops for parallel testing of different alternatives oilfield chemicals or different product types.Each loop is operated seperately Cleaning and refill is possible while other loops are still runnings.

Features:

  • Up to 6 pressurized test loops.
  • Hot and cold bath for stress test.
  • Computer controlled, automated data acquisition.
  • Easy handling
  • Open and closed loop testing
  • Small sample volumes.

 

Applications:

  • Observation of scale in pipelines and water pipes.
  • Development of inhibitors.
  • Optimization of inhibitor concentartion.
  • Optimization of water treatments.
  • Quality control.

Note: Price may vary depending on configuration & accessories.

Additional Information:

  • Item Code: DySL

View Complete details

get quote request a call back
  • Wax Flow Loop
  • Wax Flow Loop
Wax Flow Loop

Wax Flow Loop

Rs 77 Lakh  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Weight72 Kg
Voltage230 V
Temperature Range-10 to 80 degree C
Dimension130*60*70
ConditionNew
Flow rate0.3 to 30 ml/min
Pressure range0 to 5 bar
Wax Flow Loop by PSL Systemtechnik is a compact laboratory instrument to research deposition effects of waxes, paraffins and asphaltenes in pipelines.
The Wax Flow Loop simulates pipeline conditions by a test capillary, which the sample is pumped through.Only 50 ml of sample amount is sufficient to know about the efficiency and effectiveness of wax inhibitors.The Wax Flow Loop also provides the possibility to assay the efficiency and effectivenes of dissolvers. This feature allows to execute Pipeline Restart Tests and Yield Stress Tests.The Wax Flow Loop is an instrument to examine wax deposition to the inner wall of the capillary via differential pressure and wax crystallisaion in the medium itself via differential temperature.The differential pressure and -temperature are continously measured and displayed as real-time diagrams on the monitor . This allows precise conclusions about development of wax depositions and crystallisation in the medium during a test run.Experiments can be run with open or closed loop mode. In open loop mode the sample is lead to a waste container. The closed loop mode is suited to run long-time experiments. In this mode, the sample is pumped back to the sample container.

Features:

  • Fully automated
  • Exchangeable model pipeline
  • Small sample volume is requied (50ml)
  • Shock-cooling effect to maximise deopsition effect & shorten test time
  • Real time diagrams

Applications:


  • Research on deposition of wax, paraffin & asphaltene
  • Analysis of wax crystallisation
  • Testing of wax dispersants
  • Testing of pipeline coatings
  • Development & optimization of inhibiting agents & dissolvers
  • Quality control


Note: Price may vary depending on configuration & accessories.

Additional Information:

  • Item Code: WL

View Complete details

get quote request a call back
Cold Finger Mobile mCF2

Cold Finger Mobile mCF2

Rs 45 Lakh  / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Voltage230V
Weight9 Kg
Temperature-5 ... +65 DegreeC (Cold Finger)
I Deal InNew Only
Number of measuring places:2 Fingers
Sample Temperature+30 ... +100 DegreeC
Dimensions (WxDxH):25 x 55 x 54 cm (main unit)
Finger rotation speed:0 / 480 .. 1200 rpm
Sample Volume70 - 80 ml
Cold Finger Mobile  mCF2

Application: Waxcontent / Wax deposition

•Temperature fingers:-5 .. 65 °C
•Temperature samples:30 .. 100°C
•No. of fingers:2
•Sample volume: 70 – 80 ml/ test

•Further benefits:

- Portable with transport case
- Reproducible results
- Small,re -usable sample volume

Additional Information:

  • Item Code: mCF2

View Complete details

get quote request a call back
  • Differential Scale Loop DSL
  • Differential Scale Loop DSL
Differential Scale Loop DSL

Differential Scale Loop DSL

Price on Request

Product Brochure

Automation GradeAutomatic
BrandPSL Germany
Pipe2 meter, stainless steel
PurposeExamination of scale deposition and blocking in pipe line
Pressureup to 400 bar
Tempup to 350degc
Examination of Scale Formation in Pipelines with the Differential Scale Loop. A fully automated laboratory device is a tube blocking system to examine the precipitation and deposition of scale and other salt crystals in pipework systems like oil or water pipelines.


Features:
  • Small sample volumes
  • Automated tests with decreasing inhibitor concentrations
  • Automated scale detection and cleaning procedure
  • Exchangeable model pipeline
  • Overnight runs possible
  • Up to 400 bar (5800 psi)


Applications:


  • Development of inhibitors
  • Testing of oil or water treatment additives (Inhibitors / Dissolvers)
  • Quality control


Note: Price may vary depending on configuration & accessories.

Additional Information:

  • Item Code: DSL
  • Pay Mode Terms: L/C (Letter of Credit)

View Complete details

get quote request a call back
  • Cold Finger Constant Shear CFCS
  • Cold Finger Constant Shear CFCS
  • Cold Finger Constant Shear CFCS
Cold Finger Constant Shear CFCS

Cold Finger Constant Shear CFCS

Rs 120 Lakh  / PieceGet Best Price

Product Brochure

SizeDim - 55 x 59 x 118 cm + PC, thermostats
Energy ConsumptionPower Consumption - 3000W
Product CodeCFCS
PowerPower Consumption - 3000W
Weight100 Kg
VolumeMax Sample vol - 250 ml
VoltageInput - 230 V~ or 115 V~+30 ... +90 DegreeC
Temp. RangeSample Temp. +30 ... +90 DegreeC
Application: Waxcontent / Wax deposition
•Tempearture fingers:-5 .. 65 °C
•Temperature samples:30 .. 90°C
•No. of fingers:6
•Samplevolumevolume:100 or 250 ml/ test
•Further benefits:
Constantshear by rotating fingers
Flexibletest volume
Closedtest chamber for reducedevaporation

View Complete details