Product Details:
Minimum Order Quantity | 1 Piece |
Weight | 26 Kg |
Temperature Range | -30 to 150 degree C |
Cooling or heating power | Max. 480 W or max. 1050 W |
Dimensions | 26*16*38 cm |
Power consumption | Max. 2100 W |
Pressure | Ambient |
Viscosity range | 3 mPas to 100000 mPas |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model | TR |
Automation Type | Automatic |
Usage/Application | Efficiency analysis of DRA |
Dimensions | 180*80*175 cm |
Temperature Range | -10 to 80 Degree C |
Brand | PSL Systemtechnik |
The Turbulence rheometer (TR) by PSL Systemtechnik is a fully automated laboratory plant to research fluid currents in pipelines.The plant enables significant time-savings in test series and has a compact design. An integrated PC with operating software allows for an easy handling, supervision and evaluation of test series.The measurement principle of the TR is an hydraulic piston, which moves the sample piston.
The effects of the Drag Reducing Agent (DRA) can be observed by direct pressure measuring or calculation of the differential pressure-loss in separate segments of the capillary. To guarantee best measurement results the TR was designed without edges or changes in diameter. Special geometries of the piston and piston head enable constant acceleration values at the injection and thereby minimize shear forces.
Features:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Automation Grade | Automatic |
Brand | PSL Germany |
Temp | up to 350degc |
Pressure | up to 400 bar |
Pipe | 2 meter, stainless steel |
Purpose | Examination of scale deposition and blocking in pipe line |
Applications:
Additional Information:
Product Details:
Weight (g) | 21 Kg min |
Automation Grade | Automatic |
Application | Gas hydrate formation |
test samples | 2, 6, 8 or 20 samples |
Temp | -10 to + 60degC |
Presure | up to 200 bar |
Rocking Cell System RC5-Automated hydrate test system for inhibitor screening and compatibility testing.The Rocking Cell uses one of the most stringent condition of the currentlyaccepted methods for research on hydrate inhibitors and influence of corrosion inhibitors. The measuring principleof the rocking cell is based on the steady tilting of cooled, pressurised test cells (rocking cells).
While tilting, a ball inside the camber is steadily rolling over the length of the test chamber, thereby blending the fluid-gas mixture.
The movement of the ball creates strong shear forces and turbulences in the test chamber. Thus, the conditions in pipelines are reproduced.
For testing the test chambers are filled with a sample fluid (water or other) and a certain amount of inhibitor. The test chambers are cooled down to a given test temperature. Subsequently, the central gas supply is used, to fill each chamber to the individually required pressure of up to 200 bar (2,900 psi).The 5 test chambers are mounted on a movable axis in a closed cooling bath with cooling liquid. Only this axis is tilted during the test. This offers the advantage, that only the test chambers are moved but not the cooling bath itself.
The Rocking Cell is extendable up to 10 test chambers.
The test chambers are magnetically attached and can thus be easily removed for filling or cleaning.
The compact Rocking Cell requires only a small amount of space and is equipped with an integrated PC.
Features:
Note:Price may vary depending on configuration & accessories.
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Automation Grade | Automatic |
Purpose | Examine Gas Hydrate Formation |
No of samples | 2,6,8,20 test cells |
Rocking rate | adjustable 1-20/min |
Racking angle | adjustable 1- 45 deg |
Temp | -10 to +60degC |
Pressure | up to 200 Bar |
The Sapphire Rocking Cell is a laboratory instrument to research and test low-dosage hydrate inhibitors (LDHI), corrosion inhibitors (KI), anti-agglomerates (AA) and kinetic hydrate inhibitors (KHI) and also multi-phases. The full view polished test cells are made of sapphire glass.The sapphire test cells are completely transparent.
The sapphire Rocking cell is available in three designs.
The Rocking Cell RCS2 with upto 2 test cells.
The Rocking Cell RCS6 with up to 6 test cells are models for small spacing, e.g to be placed in a fume hood.
The Rocking cell RCS 20 is a stand alone rig installation with up to 20 test cells.
Examination of Gas Hydrate Formation with the Gas Hydrate Autoclaves. The Gas Hydrate Autoclaves GHA 200 and GHA 350 by PSL System technique are hydrate test cells for research of the effectivity and efficiency of kinetic and thermodynamic gas hydrate inhibitors, as well as anti-agglomerates.
Features:
Applications:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Automation Grade | Automatic |
Brand | PSL systemtechnik |
Voltage | 230V |
Temperature | 30 to 200 degree C |
Weight | 35 Kg |
Tested sample condition | liquid & vapour phase |
Measuring range | 0.1 to 10000 ppm in liquids/ 1 to 1000 ppm in vapours |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Automation Grade | Automatic |
Brand | PSL |
Temperature | -10 to 60 degreeC |
Weight | 45 Kg |
Pressure Range | upto 350 bar |
Dimensions | 60*60*110 cm |
Additional Information:
Product Details:
Automation Grade | Automatic |
Type | Portable |
Brand | PSL Germany |
ASTM | ASTM D 5985 |
Temp | -55 to + 150degc |
Method | Rotational |
It is characterized by high accuracy and reproduceability of measurements. By use of thermoelectric module, it does not require any external cryostat.The Pour Point Tester have been designed to meet the broad variety of customer's demands.They are accurate and reliable as well as portable and light weight.
Features:
Applications:
Additional Information:
Product Details:
Viscosity | 5 - 100000 mPas |
Model | HPV |
Brand | PSL systemtechnik |
Usage/Application | Absolute viscosity measurement from low to very high |
Pressure | upto 1500 bar |
Temperature | -20 to 200 degree C |
Additional Information:
Product Details:
Flow rate | 0.3 to 30ml/min |
Power Consumption | 300 w |
Pressure | up to 700 bar |
Purpose | Test asphaltene stability |
Temp | -20 to 300 DegC |
Test Samples | Measures in very dark, undiluted crude |
weigth | 38 Kg |
It is available as a stand-alone device or as a complete measurement system with pump, cryostat and pressure autoclave with integrated stirrer. The adjustable light intensity makes it possible to measure even dark crudes undiluted.
Features:
Applications:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Condition | New |
Weight | 90 Kg |
Temperature Range | 30 to 120 degree C |
Dimension | 55*59*118 cm |
Cold finger temperature | -5 to 65 Degree C |
Pressure | Max. 172 bar |
Sample volume required | 60 - 80 ml |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Condition | New |
Weight | 72 Kg |
Voltage | 230 V |
Temperature Range | -10 to 80 degree C |
Dimension | 130*60*70 |
Pressure range | 0 to 5 bar |
Flow rate | 0.3 to 30 ml/min |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Temperature (Deg. Celsius) | -10 t0 150degC |
Voltage (V) | 230V |
Weight (g) | 130 Kg |
Automation Grade | Automatic |
Power Source | AC supply |
Brand | PSL Germany |
No of test loops | max 6 |
In respect to extensive testing demands, the DySL is specially designed for multiple loop test runs.It comprises up to 6 test loops for parallel testing of different alternatives oilfield chemicals or different product types.Each loop is operated seperately Cleaning and refill is possible while other loops are still runnings.
Features:
Applications:
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Insulation Wall | Double Wall |
Automation Grade | Fully Automatic |
Material | Stainless Steel |
Brand | PSL Systemtechnik |
Type of Sterilizer | Gas hydrate autoclave |
Model | GHA200 |
Usage/Application | Research on gas hydrate inhibitors |
Pressure Range | upto 250 |
Temperature Range | -10 to 60 degreeC |
Voltage | 230V |
Weight | 40-45 Kg |
Working Pressure | upto 200/350 bar |
Power Consumption | max. 2200 W |
Additional Information:
Product Details:
Automation Grade | Automatic |
Interface | 1 x USB |
Weight | 9 KG |
Voltage | 110-240 VAC |
Height | 0.125 MM |
Power | Max. 30 W |
Stability Analyzer for Heavy Fuel is used for stability control of heavy fuel oils, compatibility of blends and effect of additives. It measures the stability reserve of heavy fuel oils upon ageing simulation (precipitation of asphaltenes in alkane). It only takes one click and 15 minutes to measure the stability of heavy fuel oils. The method is accurate, repeatable and objective, it gives stability as a quantitative number. The instrument is easy to use, portable and robust.
Features:
Additional Information:
Product Details:
Condition | New |
Weight | 3 Kg |
Dimension | 26*38*16 cm |
Minimum sample amounts | 50 ml |
By combining the high precision thermal conductivity sensor with a high dynamic wide range heating/cooling device, a new standard on the field of thermal conductivity measurements could be set.The measurement principle is based on a resistance measurement at a hot wire with a diameter of only 100m.
Features:
Applications:
Additional Information: